Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Issue

SIM tries to change to the Arellia PL but ends up switching back to the Product listing it was already on

Resolution

Remove and save the files InstallHistoryPl.xml and InstallHistoryPl.xml from the \Altiris\Symantec Installation Manager\ directory.  Then run SIM and switch to the Arellia PL.

A new set of these files will be created.  When switching back to the Symantec or other PL put the old files back.

Cause

The SIM history file has been corrupted by manual intervention in the installed solutions

  • No labels